ESP EX-400 Průvodce řešením problémů

Procházejte online nebo si stáhněte Průvodce řešením problémů pro Kytary ESP EX-400. ESP EX-400 Troubleshooting guide [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
F-15-108-A
May, 1997
ESP-400
CUTTING POWER SOURCE
P/N 33518
MAINTENANCE MANUAL
PANEL
REMOTE
CURRENT CONTROL
These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the principles of operation
and safe practices for electric welding equipment, we urge you to read our booklet, "Precautions and Safe
Practices for Arc Welding, Cutting, and Gouging", Form 52-529. Do NOT permit untrained persons to install,
operate, or maintain this equipment. Do NOT attempt to install or operate this equipment until you have read
and fully understand these instructions. If you do not fully understand these instructions, contact your supplier
for further information. Be sure to read the Safety Precautions (Section I) before installing or operating this
equipment.
Be sure this information reaches the operator.
You can get extra copies through your supplier.
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - CUTTING POWER SOURCE

F-15-108-AMay, 1997ESP-400CUTTING POWER SOURCEP/N 33518MAINTENANCE MANUALPANELREMOTECURRENT CONTROLThese INSTRUCTIONS are for experienced operators.

Strany 2 - USER RESPONSIBILITY

103.1 GeneralIf this equipment does not operate properly, stop work immediately and investigate the cause of the malfunction.Maintenance work must b

Strany 3 - SAFETY PRECAUTIONS

11A. Visual Analysis For Defective BR/BBR Components.1. Remove top and left side panels of Power Source. Inspect the 500 A BR fuse links (F3 and F4)

Strany 4

12determine the specific component. Electrical isolation is accomplished by unbolting the pigtail ofthe diode being tested.(b) If one or more fuse li

Strany 5 - DESCRIPTION

13(c) Ohmmeter check of SCRs (group or individual).1. Place one test probe on the POS heatsink (same as the shunt) and touch the other test probeto ea

Strany 6 - SECTION 2 DESCRIPTION

14(c) An SCR is bad if it shows no, or very low resistance, in either direction.D. Replacing Faulty SCRs and Diodes.1. Make sure that heatsink mountin

Strany 7 - DESCRIPTIONSECTION 2

15SECTION 4 TROUBLESHOOTING4.1 GeneralDISCONNECT PRIMARY POWER AT WALL SWITCH, OR CIRCUIT BREAKER,BEFORE ATTEMPTING INSPECTION OR WORK INSIDE OF THE

Strany 8

16SECTION 4TROUBLESHOOTING2. Faulty SCRs or diodes in Boost Bridge assembly. Check per Section 3, paragraph 3.4, steps A and C.3. SCR logic board def

Strany 9

17SECTION 4TROUBLESHOOTINGFigure 4-1. ESP-400 Power Source Schematic DiagramD-33071-B

Strany 10 - MAINTENANCE

18SECTION 4Figure 4-2. ESP-400 Power Source Wiring Diagram (Sheet 1 of 2)TROUBLESHOOTINGD-33072-B

Strany 11 - MAINTENANCESECTION 3

19SECTION 4Figure 4-2. ESP-400 Power Source Wiring Diagram (Sheet 2 of 2)TROUBLESHOOTINGD-33072-B

Strany 12

2SECTION TITLE PAGEPARAGRAPHSection 1 Safety ...

Strany 13

20SECTION 5 REPLACEMENT PARTS5.1 GeneralReplacement Parts are illustrated on the following figures. When ordering replacement parts, order by pa

Strany 14

21SECTION 5 REPLACEMENT PARTSFigure 5-1. ESP-400 Power Source (Front View)1234516156, 7, 89101113*Any linear potentiometer, 5K to 25K ohms, will wor

Strany 15 - SECTION 4 TROUBLESHOOTING

22SECTION 5 REPLACEMENT PARTSFigure 5-2. ESP-400 Power Source (Right Side View)1234567810 9REF: BLACK JUMPER WIREDISCONNECTED FROM C22(+)FOR PARALL

Strany 16 - TROUBLESHOOTING

23SECTION 5 REPLACEMENT PARTSFigure 5-3. ESP-400 Power Source (Left Side View)15166431, 2REF: PILOTARC WORKREF: NEGOUTPUTTERMINALSREF: WORK/POS. OUT

Strany 17

24REPLACEMENT PARTSSECTION 5Figure 5-4. ESP-400 Power Source (Top View)1414147131211 71067954321ItemNo.QtyReq.PartNo.Description CircuitSymbol123456

Strany 18

25REPLACEMENT PARTSSECTION 5ItemNo.QtyReq.PartNo.Description CircuitSymbol123456789101122336213134206235795175695006667674367234892W11676770950527676

Strany 21

F-15-108 5/97 3C Printed in U.S.A.IF YOU DO NOT KNOW WHOM TO CALLTelephone: (800) ESAB-123/ Fax: (803) 664-4452/Web: http://www.esab.comHours: 7:30 AM

Strany 22

3WARNING: These Safety Precautions are foryour protection. They summarize precaution-ary information from the references listed inAdditional Safety In

Strany 23

4FUMES AND GASES -- Fumes andgases, can cause discomfort or harm,particularly in confined spaces. Donot breathe fumes and gases. Shield-ing gases can

Strany 24 - SECTION 5

5SECTION 2DESCRIPTION2.1 IntroductionThe ESP-400 Plasma Power Source is designed for high speed plasma cutting applications. It is normally used w

Strany 25

6SECTION 2 DESCRIPTIONThe ESP-400 is powered by a three-phase main transformer which combines with solid state control to provide volt-amperes curve o

Strany 26

7DESCRIPTIONSECTION 2Figure 2-1. Volt-Ampere Curves THE VREF DESIGNATION SHOWN ON THE TYPICAL V/A CURVES (ABOVE) CORRESPONDSTO AN ABSOLUTE VOLTAGE

Strany 27

8B. For single Power source operation, either the master or the slave unit may be used, provided items 1. through 5.below are addressed. It is not nec

Strany 28

9TO CHANGE TO 380 V OR 415 V INPUT:On the main transformer (T1) - both master and slave:For 415 V input, move the wire from H4 to H3 for all three co